Make comments more clear
This commit is contained in:
+7
-4
@@ -1,8 +1,11 @@
|
||||
; Registers:
|
||||
; r16: timer0 start and stop operations
|
||||
|
||||
start_blink:
|
||||
ldi r16, (1 << OCF0A) ; Clear timer status flag
|
||||
ldi r16, (1 << OCF0A) ; Write Output Compare Flag 0 A to 1
|
||||
out TIFR, r16 ; Clear Timer0 interrupt flag register
|
||||
|
||||
clr r16 ; Clear register
|
||||
clr r16 ; Cleanup register
|
||||
out TCNT0, r16 ; Reset Counter to 0
|
||||
|
||||
ldi r16, (1 << CS02) | (1 << CS00) ; Load prescaler value (00000101 = prescaler 1024)
|
||||
@@ -16,9 +19,9 @@ stop_blink:
|
||||
cbi PORTB, PB0 ; Set LED off
|
||||
|
||||
clr r16 ; Cleanup register
|
||||
out TCCR0B, r16 ; Stop timer0 by clearing prescaler
|
||||
out TCCR0B, r16 ; Stop timer0 by clearing prescaler
|
||||
|
||||
ldi r16, (1 << OCF0A)
|
||||
out TIFR, r16 ; Clear Timer0 interrupt flag register
|
||||
out TIFR, r16 ; Clear timer0 interrupt flag register
|
||||
|
||||
reti
|
||||
|
||||
+19
-15
@@ -1,28 +1,32 @@
|
||||
; Timer0 is static and used for the led
|
||||
; Registers:
|
||||
; r16: timer0 setup (can reuse after ret)
|
||||
; r17: timer1 dynamic setup (always needed)
|
||||
|
||||
; Timer0 (static, low precision)
|
||||
timer0_set:
|
||||
ldi r16, (1 << WGM01) ; Load 00000010 to register (bit 1=CTC)
|
||||
out TCCR0A, r16 ; On T/C Control Register A, enable CTC and
|
||||
ldi r16, (1 << WGM01) ; Write CTC (Clear Timer on Compare) to 1
|
||||
out TCCR0A, r16 ; On T/C Control Register A enable CTC waveform
|
||||
|
||||
ldi r16, 244 ; Load counter target limit value (ticks)
|
||||
out OCR0A, r16 ; Compare target to current counter
|
||||
out OCR0A, r16 ; Load target for compatison with TCNT0
|
||||
|
||||
ldi r16, (1 << OCIE0A) ; Output Compare Match A Interrupt Enable
|
||||
out TIMSK, r16 ; Allow Timer0 to interrupt (mask register)
|
||||
ldi r16, (1 << OCIE0A) ; Write Compare Match A Interrupt Enable to 1
|
||||
out TIMSK, r16 ; Allow Timer0 to interrupt
|
||||
|
||||
ret
|
||||
|
||||
; Timer1 will be dynamically changed in main (tempo)
|
||||
timer1_set:
|
||||
;timer1_set:
|
||||
; Load 10011011 to register:
|
||||
; CTC1 (Bit 7): Reset timer to 0 when it matches OCR1C
|
||||
; COM1A0 (Bit 4): Toggle OC1A (PB1) when it matches OCR1A
|
||||
; CS13, CS11, CS10 (Bits 3,1,0): Prescaler 1024 (1011)
|
||||
ldi r16, (1 << CTC1) | (1 << COM1A0) | (1 << CS13) | (1 << CS11) | (1 << CS10)
|
||||
out TCCR1, r16 ; On T/C Control Register 1, enable: CTC1 COM1A0 CS13 CS11 CS10
|
||||
; ldi r17, (1 << CTC1) | (1 << COM1A0) | (1 << CS13) | (1 << CS11) | (1 << CS10)
|
||||
; out TCCR1, r16 ; On T/C Control Register 1, enable: CTC1 COM1A0 CS13 CS11 CS10
|
||||
|
||||
timer1_use:
|
||||
ldi r16, 256 ; Load counter total value (ticks)
|
||||
ldi r16, 5 ; Load counter on value (ticks)
|
||||
; //TODO: change r16 on main and then call timer1_dyn to use the value already on r16 (so its dynamic)
|
||||
out OCR1C, r16 ; Compare target to current counter (frequency)
|
||||
out OCR1A, r16 ; Compare target to current counter (phase shift)
|
||||
;timer1_use:
|
||||
; ldi r17, 256 ; Load counter total value (ticks)
|
||||
; ldi r17, 5 ; Load counter on value (ticks)
|
||||
; //TODO: change r17 on main and then call timer1_dyn to use the value already on r16 (so its dynamic)
|
||||
; out OCR1C, r17 ; Compare target to current counter (frequency)
|
||||
; out OCR1A, r17 ; Compare target to current counter (phase shift)
|
||||
|
||||
Reference in New Issue